C. static Accuracy or Steady-State Error
In order to assess power controllability of the proposed control scheme, its static accuracy, and determine parameters governing power control static accuracy, steady-state error (SSE) of the SPCS should be calculated. Standard formulae of SSE can not be used, because neither the power feedback signal nor error signal exist in the SPCS. Basic definition will be used to calculate SSE.