3.2.2. Uniaxial compression test The quasistatic, uniaxial parallel plate compression test was performed on the nuts. The load was applied along the lateral axis, using a compression testing machine, increasing the load progressively at a constant rate of 4 mm/min until the nuts cracked. The slow speed allowed each nut to be compressed for an appreciable time before it cracked.