Protective coatings are widely used in conventional drug release systems but it has been shown in this report that electrochemical activation through the imposition of a sufficiently negative potential can induce controlled rupture of a cellulose acetate phthalate film. Electrochemical generation of hydrogen bubbles and the subsequent mechanical strain can enable rapid, on demand, release rather than relying on the gradual solubilisation of the film in solutions of higher pH.