Digital simulation and laboratory tests demonstrated that under the action of a constant DC source, the DSP- based active filter performed complete harmonic current suppression, and instantaneous reactive and oscillating active power compensation, under all circumstances of firing angle variations. When the active filter is supplied by a DC capacitor, a partial compensation is achieved, that improves when the amount of instantaneous reactive power becomes larger than the instantaneous oscillating active power.