In the first option, hot exhaust from a gas turbine replaces the air entering the existing boiler, thus eliminating the need for an air pre-heating system and reducing the boiler fuel requirements. By this integration, generating capacity is increased up to 50% and efficiency by as much as 15%. The main drawback is represented by the need of a new high temperature combustion air system and special high temperature and low O2 burners [8].