4. Conclusion
It can be concluded that a stability indicating HPLC–UV method for determination of curcumin in C. longa extract and emulsion was successfully developed. The method was rapid, simple, precise, sensitive and specific for the analysis of curcumin in emulsion.
Curcumin was stable against oxidation and heat, but susceptible to acid and alkali and very susceptible to UV degradation