Fire detection has been usedin many applications such as Forest fire Prevention systems, surveillance of volatile labs, etc. In this paper, we have proposed a new technique that implements a new fire detection algorithm. We have used MTS300CA that shows a high ability of monitoring in the MANET areas. The approach is fast, easy, and it provides a practical solution to the detection problem for either accuracy of data or power consumption. The system has a success rate of 92% for a large set of scenarios. Our implementation could prove high result not only in detecting the fire but also in verifying the fire location specifically.
This work is extended in the by using the IMB400 multimedia boards and using filtering mechanisms and computer vision technology to improve the accuracy of detection as well as the exact location of the fire.