This test method describes the laboratory determination
of water and sediment in crude oils by means of the centrifuge
procedure. This centrifuge method for determining water and
sediment in crude oils is not entirely satisfactory. The amount
of water detected is almost always lower than the actual water
content. When a highly accurate value is required, the revised
procedures for water by distillation, Test Method D 4006 (API