b. selection of filter and sample size: Choose sample volume to yield between 2.5 and 200 mg dried residue. if volume filtered fails to meet minimum yield, increase sample volume op to 1 L. if complete filtration takes more than 10 min, increase filter diameter or decrease sample volume.
c. sample analysis: Assemble filtering apparatus and filter and begin suction. wet filter with a small volume of reagent-grade water to seat it. stir sample with a magnetic stirrer at a speed to shear larger particles, if particle size. Centrifugal force may separate particle by size and density, resulting in poor precision when point of sample withdrawal is varied. while stirring, pipet a measured volume onto the seated glass-fiber filter. for homogeneous samples, pipet from the approximate middepth and container but not in vortex. choose a point both middepth and midway between wall and vortex. wash filter with three successive 10 ml volume of the reagent-grade water, allowing complete drainage between washings, and continue suction for about 3 min after filtration is complete. sample with high dissolved solids may require additional washings. carefully remove filter from filtration apparatus and transfer to an aluminum weighing dish as a support. Alternatively, remove the crucible and filter combination from the crucible adapter if a Gooch crucible is used. Dry for at least 1 h at 103-105c in an oven, cool in a desiccator to balance temperature, and weigh. repeat the cycle of drying , cooling, desiccating,and weighing until a content weight is obtained or until the weight change is less than 4% of the previous weight or 0.5 mg, whichever is less. Analyze at least 10% of all samples in duplicate. Duplicate determinations should agree within 5% of their average weight. if volatile solids are to be determined, treat the residue according to 2540E.
b. selection of filter and sample size: Choose sample volume to yield between 2.5 and 200 mg dried residue. if volume filtered fails to meet minimum yield, increase sample volume op to 1 L. if complete filtration takes more than 10 min, increase filter diameter or decrease sample volume.c. sample analysis: Assemble filtering apparatus and filter and begin suction. wet filter with a small volume of reagent-grade water to seat it. stir sample with a magnetic stirrer at a speed to shear larger particles, if particle size. Centrifugal force may separate particle by size and density, resulting in poor precision when point of sample withdrawal is varied. while stirring, pipet a measured volume onto the seated glass-fiber filter. for homogeneous samples, pipet from the approximate middepth and container but not in vortex. choose a point both middepth and midway between wall and vortex. wash filter with three successive 10 ml volume of the reagent-grade water, allowing complete drainage between washings, and continue suction for about 3 min after filtration is complete. sample with high dissolved solids may require additional washings. carefully remove filter from filtration apparatus and transfer to an aluminum weighing dish as a support. Alternatively, remove the crucible and filter combination from the crucible adapter if a Gooch crucible is used. Dry for at least 1 h at 103-105c in an oven, cool in a desiccator to balance temperature, and weigh. repeat the cycle of drying , cooling, desiccating,and weighing until a content weight is obtained or until the weight change is less than 4% of the previous weight or 0.5 mg, whichever is less. Analyze at least 10% of all samples in duplicate. Duplicate determinations should agree within 5% of their average weight. if volatile solids are to be determined, treat the residue according to 2540E.
การแปล กรุณารอสักครู่..

ข. การเลือกตัวกรอง และขนาดตัวอย่าง : เลือกหมวดตัวอย่างผลผลิตระหว่าง 2.5 และ 200 mg กากแห้ง ถ้ากรองไม่พบปริมาณผลผลิตน้อย เพิ่มปริมาณถึง 1 ลิตร ถ้า OP ตัวอย่างการกรองที่สมบูรณ์ใช้เวลามากกว่า 10 นาที เพิ่มกรองขนาดหรือปริมาณตัวอย่างลดลง การวิเคราะห์ตัวอย่าง
c : ประกอบเครื่องกรองและตัวกรอง และเริ่มดูดกรองเปียกด้วยปริมาณขนาดเล็กของน้ำเกรด 3 ที่นั่งค่ะ ตัวอย่างแม่เหล็ก stirrer กวนที่ความเร็วเฉือนอนุภาคที่มีขนาดใหญ่ ถ้าอนุภาคขนาด แรงเหวี่ยงอาจแยกอนุภาคตามขนาดและความหนาแน่น ส่งผลให้ความแม่นยําจนเมื่อจุดของตัวอย่างถอนที่แตกต่างกัน ในขณะที่กวน , ปิเปตวัดระดับเสียงบนที่นั่งใยแก้วกรอง อย่างเป็นเนื้อเดียวกันปิเปตจาก middepth ประมาณและภาชนะ แต่ไม่ได้อยู่ในน้ำวน . เลือกจุดทั้ง middepth และกึ่งกลางระหว่างผนังกับ Vortex . ล้างกรองด้วยสามต่อเนื่อง 10 มิลลิลิตร ปริมาณของสารเคมีเกรดน้ำ ให้ระบายน้ำสมบูรณ์ระหว่าง washings และยังคงดูดประมาณ 3 นาทีหลังจากการกรองที่สมบูรณ์ ตัวอย่างของแข็งสูงอาจต้อง washings เพิ่มเติมอย่างเอาตัวกรองจากเครื่องกรองและโอนไปยังจานอลูมิเนียม เครื่องชั่ง เป็นต้น อีกวิธีหนึ่งคือ เอาเบ้าและกรองจากเบ้าหลอมรวมกันอะแดปเตอร์ถ้ากูชเบ้าที่ใช้คือ แห้งอย่างน้อย 1 ชั่วโมง ที่ 103-105c ในเตาอบ , เย็นในเดซิกเคเตอร์เพื่อความสมดุลของอุณหภูมิ และชั่ง ซ้ำวงจรของ desiccating แห้ง , เย็น , ,และเครื่องชั่งน้ำหนักจนกว่าเนื้อหาจะได้รับหรือจนกว่าจะมีการเปลี่ยนแปลง น้ำหนักน้อยกว่า 4 % ของน้ำหนักเดิม หรือ 0.5 มิลลิกรัม , แล้วแต่จำนวนใดจะน้อยกว่า วิเคราะห์อย่างน้อย 10 % ของตัวอย่างทั้งหมดที่ซ้ำกัน หาที่ซ้ำกันควรเห็นด้วยภายใน 5% ของน้ำหนักเฉลี่ยของพวกเขา ถ้าปริมาณของแข็งระเหยจะถูกกำหนดให้อยู่ตาม 2540e .
การแปล กรุณารอสักครู่..