All large-volume Injections for single-dose infusion and small-volume Injections are subject to the light obscuration or microscopic procedures and limits for subvisible particulate matter set forth in Particulate Matter In Injections , unless otherwise specified in the individual monograph. An article packaged as both a large-volume and a small-volume Injection meets the requirements set forth for small-volume Injections where the container is labeled as containing 100 mL or less, if the individual monograph states a test for Particulate Matter in Injections ; it meets the requirements set forth for large-volume Injections for single-dose infusion where the container is labeled as containing more than 100 mL.