As mentioned before, device datasheets give loss numbers at fixed voltage and gate resistance values as they assist in designing the conventional VSIs. In this section a
comparative study is conducted to test the hypothesis that the losses given in traditional datasheets are not linearly scalable with operating conditions, and therefore, cannot be used for designing direct AC/AC converters.