Will you please issue one Non Conformance Report (NCR) in your form. The following text shall describe the non-conformity:” For PQR-TSS-020-S and PQR-TSS-020-M are the reports of analyze of Makro tests not shown in a correct way. Reference lines for measuring of throat thickness and penetration depth are placed in wrong positions”. Suggested action is to “use as is” Reference to standard AWS D1.1/D1.1M:2010.
On Friday 2:nd November please send copies of all material certicates, copies of packing lists and inpection reports for visual inspection of welds, signed by you and me. Photo report for finished welded parts unit 1 ( for end client). Send all these documents to Mr Martin Oppermann with copy to me and and Annika Svensson