7 Summary
We have given a description of NIST’s Water Flowmeter Calibration Facility which is used by the Fluid Metrology Group to offer water flowmeter calibration services in the range; 40 to 1600 L/min. This standard has an uncertainty of 0.033% for liquid mass collections of 3000 kg, and 0.051% for 600 kg collections.
The intended audience for this document includes NIST’s water flowmeter calibration customers, and the characteristics and uncertainties claimed are intended to reflect the concerns of this audience. This document explains the method of operation of the WFCF,
38
the functions of its various components, and provides details necessary for customers wanting to submit meters for calibration (i.e., pipeline sizes, costs, turnaround time, etc.), and gives a detailed analysis of the uncertainty of its mass (or volumetric) flow measurement results. Additionally, we have given a description of typical flow calibration, including a sample calibration report.
7 สรุป
เราได้ให้รายละเอียดของ NIST น้ำอัตราการสอบเทียบโรงงานซึ่งถูกใช้โดยกลุ่มที่ให้บริการสอบเทียบมาตรวิทยาเครื่องวัดอัตราของไหลของน้ำในช่วง ; 40 - 1 , 600 ลิตร / นาที มาตรฐานนี้มีความไม่แน่นอนของ 0.033 % สำหรับคอลเลกชันของของเหลวมวล 3000 กิโลกรัม และ 0.051 ( 600 กก
คอลเลกชันผู้ชมเป้าหมายสำหรับเอกสารนี้รวมถึงการสอบเทียบ NIST น้ำปริมาณลูกค้า และลักษณะและความไม่แน่นอน อ้าง มีวัตถุประสงค์เพื่อสะท้อนให้เห็นถึงความกังวลของผู้ชมนี้ เอกสารนี้จะอธิบายถึงวิธีการดำเนินงานของ wfcf
38 , การทำงานของส่วนประกอบต่างๆ และมีรายละเอียดที่จำเป็นสำหรับลูกค้าที่ต้องการส่งเมตรสำหรับการสอบเทียบ ( เช่นท่อขนาด , ต้นทุน , เวลาตอบสนอง , ฯลฯ ) , และให้รายละเอียดการวิเคราะห์ความไม่แน่นอนของมวล หรือ ปริมาตร ) ผลการวัดการไหล นอกจากนี้ เราได้ให้รายละเอียดของการสอบเทียบอัตราการไหลโดยทั่วไป ได้แก่ ตัวอย่างการรายงาน