The momentary value of the motor rotation speed ωr is calculated on the basis of the already available information about the position angle of the rotor. Then the calculated rpm ωr together with the preset rpm r* is supplied to the input of the PI regulator that is used to calculate the new value of electric current iqs* (for the control of torque)