The results show that the pitting potential determined by these methods are more active than the pitting potentials determined by potentiokinetic and galvanokinetic methods. 1,2 The results also prove the existence of only one characteristic potential for pitting corrosion on aluminium as indicated in earlier papers. The temperature has a marked influence on the pitting potential which decreases with increasing temperature.