Given that the temperature development in foamed concrete
was found to be affected by a greater number of parameters than
normal weight concrete, existing temperature prediction models
could not be used with this material. Whilst this study has
focussed on the influence of foamed concrete mix design on
temperature development, further work on a wider range of
foamed concretes at full-scale would be required before such a
prediction model could be developed.