A north–south tracking axis orientation gives a high summer bias to annual electricity output, which is useful in California.
Superheating is carried out using natural gas. Hybrid solar/fossil operation soon showed itself to be more costeffective
and reliable at supplying peak loads than limited storage could be, but the gas usage was limited to 25% by Federal laws which were related to plant subsidies received.