A primary objective at Milliken was to
determine the minimum NOx level attainable
while maintaining marketable fly ash
production (fly ash having less than 4.5%
carbon). Variables studied at Milliken include
boiler load, reburn coal fineness,
oxygen level at the economizer, percent
reburn fuel, main burner tilt, and OFA tilt.