in analysis, set Start Frequency and End Frequency to 60 Hz, select Linear; set Total points to 1, click OK, then click the Run icon. When the simulation window opens, click View/Output File, then scroll until you find the answers indicated in Figure 17-33. As indicated, the magnitude of the current, IM(V_PRINTI), is 3.280 X 102 = 328 A, the same as we computed in Example 17-8. Now connect a 306-1.1,F capacitor across the load between points x-x, then run the simulation again. Note that source current drops to 286 A as predicted in Example 17-8.