evaluated at T=475 K and using
the water dipole moment of 1.85 D. Therefore we expect
that the wetting transition temperature calculated from
the CCST model using these two potentials be compara-
ble. If the simulation results in this work are taken to be
standard, the CCST model predicted Tw of 474 K is very
accurate indeed. It has been shown that the CCST model
usually works well in predicting the wetting behavior in-