Rating of induction motor (KW):10
Number of poles of machine:4
Stator winding connected in star
Rated frequency:50
Rated speed in rpm:1440
Rated voltage:220
Value of nominal torque:10
NO-LOAD TEST (at rated voltage and frequency)
DATA(phase values)
- - - - - - - - - - - - - - - - - - - - - - - - - -
Applied stator voltage:127
Input current:20
Input power:1000
BLOCKED ROTOR TEST(at rated stator current)
DATA(phase values)
- - - - - - - - - - - - - - - - - - - - - - - - - -
Applied stator voltage:17.32
Input current:50
Input power:1500
Per phase d.c. resistance of stator winding measured:
immediately after the blocked rotor test:0.16
Required torque:4
Enter rotor speed:1000
After applying the fuzzy logic as per the requirement of torque
the error in the current torque from the required torque is:-
Torque error =0.0063
Now value of torque is =3.9937