where �" is the damping ratio for the multistory building in its nth natural mode of vibration. However, for damping ratios less than 0.2, a range which includes most structures, the effects of damping on vibration frequencies arc negligible (see Fig. 10). The natural frequencies and modes of vibration of a structure can therefore be computed under the assumption that the structure is undamped.