3.2.2. Coating removal
If the main change occurs in the high frequency range, then the
conclusion is reached that the coating itself degrades. The rate of
degradation can be estimated from the capacitance change in time.
In most cases this would lead to a change in the product, which
might not be acceptable. An important question is whether the
container shows subsequent corrosion, because this would lead to
perforation.