Magnetorheological (MR) elastomer composites, consisting of natural rubber and carbonyl iron (CI), were
fabricated in two different forms of isotropic and anisotropic states. In the case of the anisotropic MR
elastomer sample, it was cured under an applied external magnetic field. Therefore, the dispersed CI particles
were pre-aligned in the direction of the applied magnetic field. To confirm the arrangement of CI
particles in the elastomer composite, a mapping method by scanning electron microscopy was used.
The MR effect of these MR elastomer samples was measured using a rotational rheometer under an external
magnetic field. The results showed that as the magnetic field strength increases, the storage moduli
increased depending on the angular frequency at a constant shear strain. Higher MR performance from
both the viscoelastic characteristics and MR efficiency were also observed for the anisotropic MR elastomer
compared to the isotropic MR elastomer.