Thermal contact resistance can be minimized by (1) applying a thermally
conducting liquid on the surfaces before they are pressed against each other, (2) by
replacing the air at the interface by a better conducting gas such as helium or hydrogen,
(3) by increasing the interface pressure, and (4) by inserting a soft metallic foil such as
tin, silver, copper, nickel, or aluminum between the two surfaces.