V.SIMULATION AND EXPERIMENTAL RESULTS
Computer simulation and hardware realization are used to verify the theoretical calculation. Envelopes of the original time-domain waveforms are presented Fig. 7(b) and 7(C) show transient response for 50W step command (250W to 300W, load resistance R=210).
Fig.8 show transient response for step load (R is decreased from 240 t0 210). Good agreement between theoretical analysis, computer simulation, and hardware realization ratifies the simplified power control scheme