distinguished from the uncorroded Mg2Si (Fig. 7a). With increasing immersion time in NaCl solution, the composition of Mg in Mg2Si⁎ phase continues to reduce and relative Si content increases (Fig. 7b), which can lead to the electrochemical polarity conversion [18,22].