We observed significant differences between the pre- and post-PR means for six-minute walk distance (305 ± 78 vs. 330 ± 96 m, p < 0.001) and maximal workload (33 ± 21 vs. 39 ± 20 W; p = 0.02). At equivalent workload settings, PR led to lower oxygen consumption, carbon dioxide production (VCO2), and minute ventilation. The inspiratory (operating) rib cage volume decreased significantly after PR. There were 6 patients in whom PR did not increase the maximal workload. After PR, those patients showed no significant decrease in VCO2 during exercise, had higher end-expiratory chest wall volumes with a more rapid shallow breathing pattern, and continued to experience symptomatic leg fatigue.