[23/2/2015 16:20:26] SRoque - Jose Portilha: that is normally the solution used in regions where the
power quallity is not so great
[23/2/2015 16:21:11] SRoque - Jose Portilha: but remember, that stabilizer is to be used only for the
machines power (control rotation printheads) and not for the flashes (which consume a lot of
power)
[23/2/2015 16:22:19 | แก้ไขแล้ว 16:22:25] SRoque - Jose Portilha: you can find on the bottom of
the electrical cabinet some terminals that say UPS in out, you can use those terminales to connect
the stabilizer
[23/2/2015 16:22:50] Rung: Noted
[23/2/2015 16:23:45] Rung: Plz suggestion the stabilzer.
[23/2/2015 16:24:26] SRoque - Jose Portilha: the client has two solutions
[23/2/2015 16:25:17] SRoque - Jose Portilha: 1st one stabilizer for each machine, the advantage is
that when he turns the machine of it will also turn off the stabilizer voltage
[23/2/2015 16:26:19] SRoque - Jose Portilha: 2nd one stabilizer for the two machines, carefull must
be taken because even if you turn off the machine power swith you will still have power on the
machine because the stabilizer is supplying it
[23/2/2015 16:27:19] SRoque - Jose Portilha: for the seconds solution, procedures and warning must
be placed on the machine, specially near the main switch to inform anyone that can eventually work
or do some maintenance
[23/2/2015 16:28:10] Rung: I think solutions 1 is better.
[23/2/2015 16:28:40] SRoque - Jose Portilha: yes but normally more expensive
[23/2/2015 16:33:24] SRoque - Jose Portilha: regarding the three times, the number of times doesnt
matter, if the spike is very big it will burn the inverter, if happens a lot of times in a short period of
time it will probably damage it as well
[23/2/2015 16:34:56] Rung: Okay