◊ Refer to above check, panel S was confirmed to be defected.
(at looking check process couldn't found shield didn't have screw because we have to screwing it
before checking all of function of part).
3. Checked function of the defective part at engineer process and found it didn't work in touch screen function.
4. Refer FTdM comment, IC6000 NG. Please SMT Sent IC6000 to maker analysis.
Manufacturing line was found a unit that not work the touch screen. ABA test was made and failure follow to
panel. During the analysis was detected the next: Diode test was made and it was detected a short to ground
in the point 185 from IC6000, the sample OK shows 0.507 V and the NG unit shows 0.002V.
5. Sent circuit S to supplier for deep analysis on 12-Feb-15.
6. Analysis result from maker
6.1 Description of Problem