Next, we can reduce the load voltage ripple by increasing the filter
capacitor from 1000 μF to 10,000 μF. As shown in Figure 5.6a, note the
peak-peak load voltage ripple is reduced, but at the expense of higher
peak line current (Figure 5.6b) and higher levels of harmonic distortion
in the line current (Figure 5.6c)